Dosimetric verification of dynamic tumor tracking intensity modulated radiation therapy(DTT IMRT)

来源 :The 15th Asia-Oceania Congress of Medical Physics (AOCMP2015 | 被引量 : 0次 | 上传用户:zhangyananqd
下载到本地 , 更方便阅读
声明 : 本文档内容版权归属内容提供方 , 如果您对本文有版权争议 , 可与客服联系进行内容授权或下架
论文部分内容阅读
  Purpose Dynamic tumor tracking with intensity modulated radiation therapy(DTT IMRT)function was newly installed in Vero4DRT in our hospital.The purpose of this study was to perform dosimetric verification for DTT IMRT using a chamber and a Gafchromic film.Material & Method The dosimetric verification system was comprised of a 0.13 cc ionization chamber,Gafchromic EBT3 films,a water-equivalent phantom,and a moving phantom(QUASAR platform phantom).First,the water-equivalent phantom was positioned on the QUASAR platform phantom with the chamber.Subsequently,step-and-shoot IMRT delivery was performed under the conditions as follows:(1)Stationary IMRT,(2)Non-DTT IMRT and(3)DTT IMRT.The phantom was reciprocated along superior-inferior direction by sinusoidal patterns(Amplitude:10-40 mm,Breathing cycle:2-4 s).In the dose distribution verification,the EBT3 films were inserted in the water-equivalent phantom and the IMRT delivery was performed in the same manner.The dosimetric tolerance to the planned dose was set to dose error within ±5%in each port and ±3%in total,and Gamma Pass rate > 90%.Result Absolute dosimetric verification:In Non-DTT IMRT,it was observed that the dose error was greater than the tolerance at several spots having steep dose gradient for complicated plans.On the other hand,the dose error became less than the tolerance in DTT IMRT for all patterns.Dose distribution verification:Gamma pass rate became greater than 94%for all patterns in DTT IMRT,while Gamma pass rate became lower for patterns with larger amplitude in Non-DTT IMRT.Conclusion We have demonstrated that DTT IMRT for the moving target had good agreement with Static IMRT for the stationary target in terms with dosimetry,suggesting that DTT IMRT function in the Vero4DRT system can improve the dosimetric accuracy of IMRT for the moving target.
其他文献
  PURPOSE: TomoTherapy combines CT imaging with a radiation treatment delivery system.With this unique design,TomoTherapy enables efficient daily Image-guided
会议
会议
  Background and purpose:Endoplasmic reticulum(ER)stress generated by various physiological and pathological conditions may induce an accumulation of misfolde
会议
  Purpose: Reflective-type radiochromic film(GAFCHROMCI RTQA2)is one of the most useful devices for quality assurance of radiotherapy equipment.The aim of thi
会议
  The objective of this study was to determine T2 relaxation times in high-fat(HF)diet-induced fatty liver in rats using localized point-resolved spectroscopy
会议
  Introduction:An atomic accident occurred at Fukushima 1st nuclear power plant by the eastern Japan great earthquake which occurred on March 11,2011.Radioact
会议
  Purpose: PET/CT images fusion accuracy may suffer from respiratory motion of body.To get better clinical images,it is necessary to correct PET data for moti
会议
会议
会议
  Purpose:Radionuclide therapies(RNTs)have been proved to be beneficial with respect to tumour response and in improving patients' quality of life.Radiation p
会议